Environmental Requirements
007-4522-003 105
Environmental Requirements
Table A-4 provides temperature and humidity requirements for both the rack and tower
storage systems.
Table A-5 gives other environmental specifications for both the rack and tower storage
systems.
Table A-4 Ambient Temperature and Humidity Requirements
Factor Temperature Relative Humidity Maximum Wet Bulb
Operating temperature 5 °C to 40 ° C
(41 °F to 104 ° F)
20% to 80% noncondensing 23 ° C
(73 °F)
Non-operating temperature 0 °C to 50 ° C
(32 °F to 122 ° F)
8% to 80% noncondensing 27 °C
(80 °F)
Storage temperature 1 °C to 60 ° C
(34 °F to 140 ° F)
8% to 80% noncondensing 29 °C
(84 °F)
Shipping temperature -40 °C to +60 °C
(-40 °F to 140 °F)
5% to 100% nonprecipitating 29 ° C
(84 °F)
Table A-5 Environmental Specifications
Environmental Factor Requirement
Altitude, operating 0 to 3047 m (0 to 10,000 ft)
Altitude, non-operating -305 to 12,192 m (-1000 to 40,000 ft)
Shock, operating Vertical axis 5 g peak 1/2 sine, 10 ms
Shock, non-operating 30 g 10 ms 1/2 sine
Vibration, operating 0.21 grms 5-500 Hz random
Vibration, Non-operating 1.04 grms 2-200 Hz random
Acoustics Less than 6.0 B LwA operating at 20 °C
Safety and approvals CE, UL, cUL
EMC EN55022 (CISPR22-A), EN55024 (CISPR24), FCC-A